Analisa Pengaruh Cairan Etsa HNO3 terhadap Sambungan Brazing antara Mild Steel dan Aluminium Seri 6 Menggunakan Variasi Waktu Pengetsaan

Nugroho, Eko Cahyo and , Agus Dwi Anggono, ST, M.Eng, Ph.D (2020) Analisa Pengaruh Cairan Etsa HNO3 terhadap Sambungan Brazing antara Mild Steel dan Aluminium Seri 6 Menggunakan Variasi Waktu Pengetsaan. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
Naskah Publikasi_2.pdf

Download (1MB)
[img] PDF (Halaman Depan)
Halaman Depan.pdf

Download (1MB)
[img] PDF (Bab I)
BAB I.pdf

Download (203kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (681kB) | Request a copy
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (830kB) | Request a copy
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (294kB) | Request a copy
[img] PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (9kB)
[img] PDF (Lampiran)
Lampiran Full.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (Surat Pernyataan Publikasi)
SURAT PERNYATAAN PUBLIKASI ILMIAH.pdf
Restricted to Repository staff only

Download (530kB) | Request a copy

Abstract

The development of technology in today's metalworking demands an improvement in terms of design and designs of lightweight and robust structures. The purpose of this research is to know the effect of etching in the brazing process between mild steel and aluminium against micro structures and mechanical properties. Specimens in this study were used in 6000 series aluminium, mild steel, Alusol ER4043, and HNO3 etching fluid. In this research standard for specimen making is ASTM D1002. Micro-photo test is done to compare the condition of aluminium surface and mild steel with and without etching treatment. The results showed that the tensile strength was increased by etching treatment. The highest tensile strength in the 40-minute etching treatment is 28.101 MPa. While the specimen without etching treatment is obtained lower tensile strength of 9,267 MPa. Microphoto testing resulted in a significant comparison between the metal and no etching treatment, where it was apparent that the gaps or pores were seen in the specimen with an etching treatment for 40 minutes. Keywords: Brazing, Etching Treatment, Micro Structure, Tensile Strength.

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: Brazing, Etching Treatment, Micro Structure, Tensile Strength.
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TS Manufactures
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: EKO CAHYO NUGROHO
Date Deposited: 06 Feb 2020 04:38
Last Modified: 06 Feb 2020 04:38
URI: http://eprints.ums.ac.id/id/eprint/80359