Perencanaan Struktur Gedung Hotel Asimetris 10 Lantai Dengan Dilatasi Di Malang

Prayitna, Asy Syfa Fajar and , Ir. Budi Setiawan, S.T., M.T (2026) Perencanaan Struktur Gedung Hotel Asimetris 10 Lantai Dengan Dilatasi Di Malang. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
Naskah Publikasi (4)_watermark_D100210215.pdf

Download (4MB)
[img] PDF (Halaman Depan)
Halaman depan.pdf

Download (2MB)
[img] PDF (Bab I)
Bab I.pdf

Download (756kB)
[img] PDF (Bab II)
Bab II.pdf
Restricted to Repository staff only

Download (477kB)
[img] PDF (Bab III)
Bab III.pdf
Restricted to Repository staff only

Download (4MB)
[img] PDF (Bab IV)
Bab IV.pdf
Restricted to Repository staff only

Download (2MB)
[img] PDF (Bab V)
Bab V.pdf
Restricted to Repository staff only

Download (2MB)
[img] PDF (Bab VI)
Bab VI.pdf
Restricted to Repository staff only

Download (2MB)
[img] PDF (Bab VII)
Bab VII.pdf
Restricted to Repository staff only

Download (1MB)
[img] PDF (Bab VIII)
Bab VIII.pdf
Restricted to Repository staff only

Download (1MB)
[img] PDF (Bab IX)
Bab IX.pdf
Restricted to Repository staff only

Download (740kB)
[img] PDF (Daftar Pustaka)
Daftar Pustaka.pdf

Download (571kB)
[img] PDF (Lampiran)
Lampiran.pdf
Restricted to Repository staff only

Download (6MB)
[img] PDF (Surat Pernyataan Publikasi)
Surat Pernyataan Publikasi.pdf
Restricted to Repository staff only

Download (651kB)

Abstract

Malang City is one of the developed cities that is a strategic center of trade, services, and tourist destinations in the East Java region, this makes it attract many tourists, so a hotel building is needed for visiting tourists. This study develops a 10-story hotel building design with an asymmetrical L-shaped plan that is safe, strong, and earthquake-resistant in accordance with SNI 1726: 2019 and SNI 2847: 2019 regulations. The hotel building is planned with an area of building A, namely 15x50m with a total of 10 floors with a height between floors +4m, building B is 19x51m with a total of 3 floors with a height between floors +4m. The planning method used is (SRPMK), with equivalent static analysis based on the design response spectrum. Planning includes load analysis, calculation of structural elements such as beams, columns, plates, stairs, roofs, connections, bore pile foundations. Structural analysis and modeling using ETABS v21 and SAP2000 assistance. The planning results show that it has fulfilled the requirements for ductility, stability and strength in accordance with the applicable SNI provisions.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Earthquake, Reinforced Concrete, Response Spectrum, SRPMK
Subjects: T Technology > TA Civil Engineering
T Technology > TA Civil Engineering > Teknik Kontruksi, Pondasi
Divisions: Fakultas Teknik > S1 Teknik Sipil
Depositing User: ASY SYFA FAJAR PRAYITNA
Date Deposited: 14 Apr 2026 07:45
Last Modified: 14 Apr 2026 07:45