Perencanaan Struktur Gedung Beton Bertulang Berdasarkan SNI-1726-2019 Dan SNI-2847-2019 Pada Pembangunan Hotel 6 Lantai Di Mangunsari, Batang

Sukarna, Muhammad and , Ir. Budi Setiawan, S.T., M.T. (2025) Perencanaan Struktur Gedung Beton Bertulang Berdasarkan SNI-1726-2019 Dan SNI-2847-2019 Pada Pembangunan Hotel 6 Lantai Di Mangunsari, Batang. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
D100200133_Naskah Publikasi.pdf

Download (889kB)
[img] PDF (Halaman Depan)
HALAMAN DEPAN.pdf

Download (877kB)
[img] PDF (Bab I)
BAB I.pdf

Download (181kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (142kB)
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (1MB)
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (219kB)
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (457kB)
[img] PDF (Bab VI)
BAB VI.pdf
Restricted to Repository staff only

Download (669kB)
[img] PDF (Bab VII)
BAB VII.pdf
Restricted to Repository staff only

Download (594kB)
[img] PDF (Bab VIII)
BAB VIII.pdf
Restricted to Repository staff only

Download (466kB)
[img] PDF (Bab IX)
BAB IX.pdf
Restricted to Repository staff only

Download (298kB)
[img] PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (90kB)
[img] PDF (Surat Pernyataan Publikasi)
D100200133_Surat Pernyataan Publikasi.pdf
Restricted to Repository staff only

Download (320kB)

Abstract

requires the implementation of a reliable structural system that ensures safety, strength, and serviceability. This study focuses on the structural design of a six-story reinforced concrete hotel building located in Mangunsari, designed in accordance with SNI 1726:2019 on Seismic Resistance Design Procedures for Buildings and Non-Building Structures and SNI 2847:2019 on Structural Concrete Requirements for Buildings. The objective of this research is to produce a structural design that meets national standards for strength, stiffness, and stability, The method for designing earthquake loads is the response spectrum method. The results of the analysis show that the 6-story hotel building has a mass capital participation for the X direction of 97.50% and for the Y direction of 97.62%, both of which exceed the minimum standardization of 90%. The final design dimensions consist of 30×50 cm beams, 70×70 cm columns, 13 cm thick slabs, and bored pile foundations with a diameter of 60 cm and depth of 12 m. All structural elements satisfy flexural, shear, and serviceability requirements according to SNI 2847:2019.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Reinforced concrete, SRPMK, SNI 2847:2019, SNI 1726:2019, Six-story hotel.
Subjects: T Technology > TA Civil Engineering
T Technology > TA Civil Engineering > Beton Bertulang
Divisions: Fakultas Teknik > S1 Teknik Sipil
Depositing User: MUHAMMAD SUKARNA
Date Deposited: 13 Nov 2025 11:49
Last Modified: 13 Nov 2025 11:49
URI: http://eprints.ums.ac.id/id/eprint/139411

Actions (login required)