May Muladi, Ruli and , Ir. Bibit Sugito, MT (2018) Analisa Pengaruh Putaran Spindel 800 Rpm Dan 1250 Rpm Pada Sambungan Fe-Cu Dengan Menggunakan Metode FSW (Friction Stir Welding) Single Track. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Halaman Depan)
HALAMAN DEPAN.pdf Download (842kB) |
|
PDF (Bab I)
BAB I.pdf Download (94kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (1MB) |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (1MB) |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (259kB) |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (121kB) |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (75kB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (560kB) |
|
PDF (Surat Pernyataan)
SURAT PERNYATAAN.pdf Restricted to Repository staff only Download (48kB) |
|
PDF (Naskah Publikasi)
NASKAH PUBLIKASI-239 Ruli.pdf Download (501kB) |
Abstract
This study aims to determine the tensile strength, hardness of steel joints with copper using the FSW method. Material used st37 steel, copper. in the welding process using a conventional milling machine with rotational rotation of 800 rpm and 1250 rpm, feed rate 12.5 mm / min, slope angle 10 and 1.8 mm plunge dept. using the ASTM E8M testing standard for tensile testing and ASTM E384 standard for violent testing. From the tensile strength test of Fe-Cu connections round 800 rpm has an average voltage of 320.63 Mpa and an average strain of 2.07%, while the 1250 rpm Fe-Cu connection has an average voltage of 165.28 MPa and an average strain - average 1.33%. For base metal at Fe-Cu 800 rpm Fe material has an average stress of 318.01 Mpa and an average strain of 7.62%, while Cu material has an average voltage of 388.26 MPa and an average strain of 13, 27%. For base metal at 1250 rpm Fe-Cu connection Cu material has an average voltage of 388.26 MPa and an average strain of 13.27%, while Fe material has an average voltage of 303.36 Mpa and an average strain of 9 , 46%. From the results of testing the hardness of Fe-Cu connection of rotation of 800 rpm at the stir zone area showed 270,8 HVN value and HAZ area showed 296,2 HVN value, while at 1250 rpm Fe-Cu connection at stir zone area showed 250,3 HVN and the HAZ area shows a value of 270.1 HVN. For base metal Fe-Cu 800 rpm connection in Fe material showed value of 162,4 HVN and Cu material showed 73,1 HVN value, while for base metal connection at Fe-Cu 1250 rpm Fe material showed 162,2 HVN value and material Cu shows a value of 74.2 HVN. Keywords: friction stir welding, st37 steel, copper, tensile, hardness. Spindle.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | friction stir welding, st37 steel, copper, tensile, hardness. Spindle. |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | RULI MAY MULADI |
Date Deposited: | 09 Apr 2018 07:06 |
Last Modified: | 09 Apr 2018 07:10 |
URI: | http://eprints.ums.ac.id/id/eprint/61588 |
Actions (login required)
View Item |