Efisiensi Penggunaan Plat Cendawan Terhadap Plat Konvensional Pada Gedung Pascasarjana Ums

Agia, Vinca Rosea and , Dr. Mochamad Solikin and , Ir. H. Ali Asroni, MT (2016) Efisiensi Penggunaan Plat Cendawan Terhadap Plat Konvensional Pada Gedung Pascasarjana Ums. Thesis thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf

Download (3MB)
[img] PDF (Halaman Depan)
HALAMAN DEPAN.pdf

Download (1MB)
[img] PDF (Bab I)
BAB 1.pdf

Download (215kB)
[img] PDF (Bab II)
BAB 2.pdf
Restricted to Repository staff only

Download (123kB) | Request a copy
[img] PDF (Bab III)
BAB 3.pdf
Restricted to Repository staff only

Download (858kB) | Request a copy
[img] PDF (Bab IV)
BAB 4.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (Bab V)
BAB 5.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (Bab VI)
BAB 6.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (Bab VII)
BAB 7.pdf
Restricted to Repository staff only

Download (89kB) | Request a copy
[img] PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (155kB)
[img] PDF (Lampiran)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy
[img] PDF (Pernyataan Publikasi Ilmiah)
SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf
Restricted to Repository staff only

Download (23kB) | Request a copy

Abstract

Redesign of Pascasarjana UMS Building by using flat slab aims to obtain the efficiency need of concrete material and steel reinforcement. The calculations was based on SNI-2847-2013 code and the material properties was remained (i.e.) f’c = 18,675 MPa, fyl = 400 MPa, and fyv = 240 MPa. The structure analyses were carried out using ETABS 2015, Microsoft Excel 2007, and AutoCAD 2016 was used to draw the detail results of redesign. The results are edge beam having dimension of 300x500 mm with longitudinal reinforcement of D12 and shear reinforcement of 2ϕ8-220. Column is redesign having dimension of 400x400 mm with longitudinal reinforcement of D16 and shear reinforcement of 2ϕ10-170. Flat slab is redesign having dimension of 150 mm and reinforcement of D10. Last, drop panel is redesign having dimension of 1500x1500x100 mm and reinforcement of D12. The volume of concrete after redesign is 109,17 m3 for the first floor. Comparing to volume of existing building of 154,05 m3, the redesign obtains efficiency value of 0,71. Meanwhile the volume after redesin of steel reinforcement is 5.187,80 kg for the first floor. Comparing the existing building of 27.666,64 kg, the redesign obtains efficiency value of 0,19.

Item Type: Karya ilmiah (Thesis)
Uncontrolled Keywords: beam, drop panel, efficiency, flat slab, slab.
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Pasca Sarjana > Magister Teknik Sipil
Depositing User: VINCA ROSEA AGIA
Date Deposited: 23 Apr 2016 04:46
Last Modified: 23 Apr 2016 04:46
URI: http://eprints.ums.ac.id/id/eprint/42899

Actions (login required)

View Item View Item