Agia, Vinca Rosea and , Dr. Mochamad Solikin and , Ir. H. Ali Asroni, MT (2016) Efisiensi Penggunaan Plat Cendawan Terhadap Plat Konvensional Pada Gedung Pascasarjana Ums. Thesis thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf Download (3MB) |
|
PDF (Halaman Depan)
HALAMAN DEPAN.pdf Download (1MB) |
|
PDF (Bab I)
BAB 1.pdf Download (215kB) |
|
PDF (Bab II)
BAB 2.pdf Restricted to Repository staff only Download (123kB) | Request a copy |
|
PDF (Bab III)
BAB 3.pdf Restricted to Repository staff only Download (858kB) | Request a copy |
|
PDF (Bab IV)
BAB 4.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (Bab V)
BAB 5.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (Bab VI)
BAB 6.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (Bab VII)
BAB 7.pdf Restricted to Repository staff only Download (89kB) | Request a copy |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (155kB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (3MB) | Request a copy |
|
PDF (Pernyataan Publikasi Ilmiah)
SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf Restricted to Repository staff only Download (23kB) | Request a copy |
Abstract
Redesign of Pascasarjana UMS Building by using flat slab aims to obtain the efficiency need of concrete material and steel reinforcement. The calculations was based on SNI-2847-2013 code and the material properties was remained (i.e.) f’c = 18,675 MPa, fyl = 400 MPa, and fyv = 240 MPa. The structure analyses were carried out using ETABS 2015, Microsoft Excel 2007, and AutoCAD 2016 was used to draw the detail results of redesign. The results are edge beam having dimension of 300x500 mm with longitudinal reinforcement of D12 and shear reinforcement of 2ϕ8-220. Column is redesign having dimension of 400x400 mm with longitudinal reinforcement of D16 and shear reinforcement of 2ϕ10-170. Flat slab is redesign having dimension of 150 mm and reinforcement of D10. Last, drop panel is redesign having dimension of 1500x1500x100 mm and reinforcement of D12. The volume of concrete after redesign is 109,17 m3 for the first floor. Comparing to volume of existing building of 154,05 m3, the redesign obtains efficiency value of 0,71. Meanwhile the volume after redesin of steel reinforcement is 5.187,80 kg for the first floor. Comparing the existing building of 27.666,64 kg, the redesign obtains efficiency value of 0,19.
Item Type: | Karya ilmiah (Thesis) |
---|---|
Uncontrolled Keywords: | beam, drop panel, efficiency, flat slab, slab. |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |