Harwiyanti, Retno Dwi and , Heru Subaris Kasjono, SKM., M.Kes. and , Dwi Astuti, SKM., M.Kes (2015) KEEFEKTIFAN DOSIS KOAGULAN POLY ALUMINIUM CHLORIDE (PAC) DALAM MENURUNKAN KADAR CHEMICAL OXYGEN DEMAND (COD) PADA AIR LIMBAH LAUNDRY. Skripsi thesis, UNIVERSITAS MUHAMMADIYAH SURAKARTA.
PDF (NASKAH PUBLIKASI)
NASKAH PUBLIKASI.pdf Download (1MB) |
|
PDF (HALAMAN DEPAN)
halaman depan.pdf Download (1MB) |
|
PDF (BAB I)
BAB I.pdf Download (36kB) |
|
PDF (BAB II)
BAB II.pdf Restricted to Repository staff only Download (62kB) |
|
PDF (BAB III)
BAB III.pdf Restricted to Repository staff only Download (131kB) |
|
PDF (BAB IV)
BAB IV.pdf Restricted to Repository staff only Download (36kB) |
|
PDF (BAB V)
BAB V.pdf Restricted to Repository staff only Download (46kB) |
|
PDF (BAB VI)
BAB VI.pdf Restricted to Repository staff only Download (24kB) |
|
PDF (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf Download (13kB) |
|
PDF (LAMPIRAN)
Lampiran.pdf Restricted to Repository staff only Download (2MB) |
|
PDF (PERNYATAAN PUBLIKASI ILMIAH)
SURAT PERNYATAAN PUBLIKASI.pdf Restricted to Repository staff only Download (451kB) |
Abstract
Chemical Oxygen Demand (COD) is one of the parameters contained in the laundry waste water. The higher levels of COD in water indicates that the water pollution is also higher. Waste water measurement results Pratama Laundry indicate COD concentration of 385.92 mg/l. This value exceeds the quality standards established. The purpose of this study was to determine the dose of PAC coagulant addition most effective way to reduce levels of COD in waste water facilities. This research was experiment with a pretest-posttest design with control group. The population in this study is the wastewater generated from the process of laundering activities Pratama Laundry produce waste water output of 200-210 liters/day and the sampling technique using a quota sampling. Statistical test using ANOVA test with the results of the analysis of data obtained p = 0.000 (p <0.01),Hareceivedmeansthatthere isthe effect of addinga coagulantPACin lowering levels ofCODinlaundry waste water. Obtainedthe highestdeclineof71.79% (108.87 mg/l) at a doseof 0.75g/l.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | Wastewater laundry, COD (Chemical Oxygen Demand), PAC (Poly Aluminium Chloride) |
Subjects: | R Medicine > R Medicine (General) |
Divisions: | Fakultas Ilmu Kesehatan > Kesehatan Masyarakat |
Depositing User: | Unnamed user with username j410110014 |
Date Deposited: | 29 Oct 2015 06:08 |
Last Modified: | 12 Oct 2021 06:23 |
URI: | http://eprints.ums.ac.id/id/eprint/38484 |
Actions (login required)
View Item |