, Iksanudin and , Nur Khotimah Handayani, S.T., M.Eng. (2022) Perencanaan Struktur Gedung Kuliah 7 Lantai Dengan Metode Sistem Ganda (Srpmk Dan Shear Wall) Di Wilayah Yogyakarta. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf Download (14MB) |
|
PDF (Halaman Depan)
HALAMAN DEPAN.pdf Download (140MB) |
|
PDF (Bab I)
BAB I.pdf Download (133MB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab VI)
BAB VI.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab VII)
BAB VII.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab VIII)
BAB VIII.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab IX)
BAB IX.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Bab X)
BAB X.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (133MB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (133MB) |
|
PDF (Surat Pernyataan Publikasi)
SURAT PERNYATAAN PUBLIKASI.pdf Download (999kB) |
Abstract
Earthquake load is a very important thing to consider in planning a building. In accordance with regulations SNI 1726 – 2019, so that the burden of earthquakes that occur can be held by the planned building structure, seismic-style are used with the double system method. The planned building design of 7 floors lecture building located in the Yogyakarta region. The structure of the building with the double system method uses a combination of the frame of the moment and the addition of shear wall. Earthquake load design used in analysis is a spectrum response method. From the result of the SAP 2000 v.20 software run analyze, obtained in mode 1 value Tc = 0.6229 seconds in the direction -Y and mode 2 value Tc = 0,5991 seconds in the direction -X. Value Ta = 0,935 seconds, so obtained the value Tc < Ta. The lateral force caused by earthquake load response spectrum in absorbed by the shear wall by 70,54% in the direction -X and 45,58% in the direction -Y. From the analysis of the calculation of the dimensions of the child beam 325/600, the parent beam 350/650, 400/700,column 720/720,750/750,780/780 and the sehar wall with thickness of 250 mm have met the requirement in SNI 2847 -2013.
Item Type: | Thesis (Skripsi) |
---|---|
Uncontrolled Keywords: | Earthquake load, Dual System, Building structure |
Subjects: | T Technology > TA Civil Engineering |
Divisions: | Fakultas Teknik > Teknik Sipil |
Depositing User: | IKSANUDIN |
Date Deposited: | 27 Jan 2022 01:32 |
Last Modified: | 27 Jan 2022 01:32 |
URI: | http://eprints.ums.ac.id/id/eprint/96705 |