Faqih, M. Izza Zulfana and , Wijianto SST, FT. M, OR (2019) Penatalaksanaan Infra Red dan Hold Relax untuk Mengurangi Nyeri, Meningkatkan Lingkup Gerak Sendi, Meningkatkan Kekuatan Otot Shoulder pada Kasus Post Orif Fraktur Humerus 1/3 Distal Dextra di RSUD Panembahan Senopati Bantul. Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf Download (322kB) |
|
PDF (Halaman Depan)
HALAMAN DEPAN-83.pdf Download (402kB) |
|
PDF (Bab I)
BAB I.pdf Download (80kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (160kB) | Request a copy |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (163kB) | Request a copy |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (201kB) | Request a copy |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (74kB) | Request a copy |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (137kB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (666kB) | Request a copy |
|
PDF (Pernyataan Publikasi)
PERNYATAAN PUBLIKASI.pdf Restricted to Repository staff only Download (156kB) | Request a copy |
Abstract
Background: Prevelention of fraktur included high one of them is fraktur humerus, fraktur usually occur because fall accident, traffic accident, trauma object sharp and blunt Purpose: Knowing the benefits of Infrared and Hold Rilex in cases of post ORIF fracture humerus 1/3 distal in reducing pain, increasing range of motion Results: after getting 3 times the therapy, the result was a reduction in tenderness T1 = 3 to T3 = 1, and a decrease in motion pain T1 = 5 to T3 = 3. Increased range of motion for active movement T1 S = 20-0-30, F = 100-0-30, T = 20-0-100, R = 50-0-90 menjadi T3 S = 30-0-40, F = 110-0-40, T = 30-0-110, 60-0-100. For strength of muscle not yet increased strength of muscle until measure 3 with value 4 on all motion Conclusion: The modality of infrared and hold relax is able to deal with disorders that occur in post orif fracture humerus 1/3 distal.
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | Infrared, Hold Rilex, Post Orif Fracture Humerus 1/3 Distal. |
Subjects: | R Medicine > RM Therapeutics. Pharmacology |
Divisions: | Fakultas Ilmu Kesehatan > Fisioterapi D3 |
Depositing User: | M.IZZA ZULFANA FAQIH |
Date Deposited: | 03 Aug 2019 04:18 |
Last Modified: | 03 Aug 2019 04:18 |
URI: | http://eprints.ums.ac.id/id/eprint/75411 |
Actions (login required)
View Item |