Analisis Pengaruh Ketidakseimbangan Beban Terhadap Efisiensi Transformator Distribusi di PT.PLN (PERSERO) Rayon Palur Karanganyar

Saputro, Ahmad Eko Yuli and , Agus Supardi, S.T., M.T (2018) Analisis Pengaruh Ketidakseimbangan Beban Terhadap Efisiensi Transformator Distribusi di PT.PLN (PERSERO) Rayon Palur Karanganyar. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Surat PErnyataan)
img007.pdf
Restricted to Repository staff only

Download (432kB) | Request a copy
[img] PDF (Naskah Publikasi)
Publikasi Ilmiah.pdf

Download (826kB)

Abstract

Abstrak Meningkatnya pembangunan di seluruh wilayah Indonesia membuat permintaan energi listrik menjadi melonjak. Oleh karena itu pendistribusian energi listrik dari gardu induk ke konsumen diusahakan agar stabil, berkelanjutan dan dapat memenuhi kebutuhan konsumsi energi listrik. Dalam proses penyaluran energi listrik sering kali terjadi pembagian beban yang tidak merata pada setiap fasanya. Ketidakseimbangan beban ini selalu terjadi karena adanya ketidaksamaan dalam pemakaian energi listrik. Ketidakseimbangan fasa R,S,T inilah yang akan menimbulkan arus yang mengalir pada penghantar netral transformator, lalu arus tersebut menyebabkan terjadinya rugi-rugi daya pada transformator. Penelitian ini dilakukan untuk mengetahui seberapa besar rugi-rugi daya yang terjadi akibat ketidakseimbangan, untuk mengetahui pengaruh ketidakseimbangan beban terhadap efisiensi transformator distribusi, dan agar dapat mengantisipasi supaya ketidakseimbangan beban dapat diminimalisir di PT. PLN (Persero) Rayon Palur Karanganyar. Metode yang digunakan adalah pengumpulan referensi dari jurnaljurnal yang berhubungan dengan judul yang diambil. Setelah pengumpulan referensi kemudian dilanjutkan dengan pengambilan data penelitian yang diperoleh dengan cara mengikuti prosedur dari pihak instansi. Tahapan selanjutnya adalah melakukan perhitungan dan menganalisis pengaruh ketidakseimbangan beban terhadap efisiensi transformator tersebut. Setelah dilakukan perhitungan dan dianalisis dapat disimpulkan bahwa ketiga transformator dalam keadaan tidak seimbang. Efisiensi transformator tertinggi terjadi pada transformator kedua ketika siang hari yaitu sebesar 97,51%, dan efisiensi transformator terendah terjadi pada transformator pertama ketika malam hari yaitu sebesar 94,90%. Ketika ketidakseimbangan beban semakin tinggi maka rugi-rugi daya pada transformator juga semakin besar, dan efisiensinya semakin rendah. Kata Kunci: Transformator Distribusi, Ketidakseimbangan Beban, Efisiensi Abstract Increasing development in all regions of Indonesia makes the demand for electrical energy to become soaring. Therefore the distribution of electrical energy from the substation to the consumers should be stabilized, continuous, and able to fulfill the needs of electrical energy consumption. In the process of electrical energy distribution, there is often an uneven distribution of load on each phase. This load imbalance always occurs due to the inequality in the use of electrical energy consumption. The imbalance phase of R, S, T will cause current flow in the neutral conductor of a transformer, then the current cause of occurrence of loss of the power transformer. This research was conducted to find out how big a power loss that occurs due to an imbalance, to know the impact of the unbalance load against the efficiency of distribution transformer, and to be able to anticipate so the unbalance load can be minimized at PT. PLN (Persero) Rayon Palur Karanganyar. The method used is the accumulation of references from journals that are associated with the title that was taken. After collecting a reference then proceed with the taking of the research data obtained by following the procedures of the institue. The next stage is to perform calculations and analyze the impact of the unbalance load against the efficiency of a transformer. After the calculation and analyzed it can be concluded that the three transformer in a unbalanced state. The highest transformer efficiency occurs at a second transformer when during the day time that is equal to 97.51%, and lowest transformer efficiency occurs at night time when the first transformer that is equal to 94.90%. When the higher of load imbalance, then the loss of the power transformer are also getting bigger, and the efficiency is getting lower. Key Words: Distribution Transformer, The Load Imbalance, Efficiency

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: Kata Kunci: Transformator Distribusi, Ketidakseimbangan Beban, Efisiensi
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: AHMAD EKO YULI SAPUTRO
Date Deposited: 24 Jul 2018 12:24
Last Modified: 24 Jul 2018 12:27
URI: http://eprints.ums.ac.id/id/eprint/63991

Actions (login required)

View Item View Item