Luthfi, Sholahudin and , Aris Budiman S.T,M.T (2018) Analisis koordinasi peralatan pengaman jaringan penyulang sumber PT.PLN Cirebon. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah publikasi)
LUTHFI UPLOAD_3.pdf Download (1MB) |
|
PDF (Surat pernyataan publikasi)
Untitled.pdf Restricted to Repository staff only Download (128kB) | Request a copy |
Abstract
An electrical distribution circuitr sometimes has disturbance. This led to PT.PLN a loss in terms of material The cause of problems there are various kinds. One of disorders that often occurs in the system of distribution that is short circuit. The need is a protection system that is reliable to deal with disorders related short circuit. The system of protection that is reliable could be stranded with disorder by using OCR (Over Current Relay). PT PLN Cirebon, have a lot of repeater to distribute electricity from Gardu subtation to consumers. One of the repeater of Rayon Sumber where in this repeater relies on protection system in the form of OCR (Over Current Relay).Research on coordination planning of OCR replacement in Source feeder. This Research begins to collect data on electricity that is needed. After that, using software ETAP 12.6 for the manufacture of a single line diagram and a simulation. The simulation by the related short circuit in the bus nearest relay. The relay and time of the relay. relay 1 Ip= 1.1 A and TMS= 0.6 s, relay 2 Ip=1.7 and TMS 0.11 s and relay 3 Ip= 1.1 A and TMS= 0.6 s.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | coordination, Over Current Relay, ETAP 12.6 |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Fakultas Teknik > Teknik Elektro |
Depositing User: | SHOLAHUDIN LUTHFI |
Date Deposited: | 30 Jul 2018 07:17 |
Last Modified: | 30 Jul 2018 07:17 |
URI: | http://eprints.ums.ac.id/id/eprint/63978 |
Actions (login required)
View Item |