Analisis Kerusakan Katup Ketika Overhaul Mesin Bulldozer Caterpillar D8R Diatas 30.000 Jam

Novianto, Herdhiawan Oscar and , Supriyono, S.T.,M.T.,Ph.D. (2018) Analisis Kerusakan Katup Ketika Overhaul Mesin Bulldozer Caterpillar D8R Diatas 30.000 Jam. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf

Download (8MB)
[img] PDF (Halaman Depan)
Halaman Depan.pdf

Download (2MB)
[img] PDF (Bab I)
BAB I.pdf

Download (165kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (500kB) | Request a copy
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (382kB) | Request a copy
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (624kB) | Request a copy
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (150kB) | Request a copy
[img] PDF (Daftar Pustaka)
Daftar Pustaka.pdf

Download (148kB)
[img] PDF (Lampiran)
lampiran.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img] PDF (Pernyataan Publikasi Ilmiah)
Surat Pernyataan Publikasi Ilmiah.pdf
Restricted to Repository staff only

Download (22kB) | Request a copy

Abstract

The Bulldozer is a heavy-duty tractor type vehicle with a chain and equipped with a blade located in front. This heavy equipment is used for the word of digging, pushing, displacing and pulling material (soil, sand,etc) The purpose of this final proect is to find out the valve damage in caterpillar D8R bulldozer machine along with the improvement that must be done. Valve damage inspection procedure is visual inspection, visual inspection is done by checking the valve whether the valve is in good condition or bad. In order to find out which one is having problem and after knowing the problem then disassembly is done to know the damage experienced. The result of the analysis shows that the problem that occurs on the machine is the engine component of the suction valve and the exhaust valve that has been damaged or no longer standard and must be repaired or replaced with standard operational procedure that is on the sution valve has a connection of 1.7 mm with service limit 2,2 mm and for the exhaust valve has a2.0 mm connection with a 2,5 mm service limit

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: overhaul, engine, suction & discharge valve damage
Subjects: T Technology > TJ Mechanical engineering and machinery