Kurniawan, Fajar and , Anto Budi Listyawan, S.T., M.Sc. (2017) Pengaruh Selimut Pada Pondasi Telapak Bujur Sangkar Pada Tanah Lempung Akibat Pembebanan. Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIKASI revisi.pdf Download (643kB) |
|
PDF (Halaman Depan)
PENDAHULUAN revisi.pdf Download (746kB) |
|
PDF (Bab I)
BAB 1.pdf Download (122kB) |
|
PDF (Bab II)
BAB 2.pdf Restricted to Repository staff only Download (114kB) | Request a copy |
|
PDF (Bab III)
BAB 3.pdf Restricted to Repository staff only Download (105kB) | Request a copy |
|
PDF (Bab IV)
BAB 4.pdf Restricted to Repository staff only Download (462kB) | Request a copy |
|
PDF (Bab V)
BAB 5.pdf Restricted to Repository staff only Download (339kB) | Request a copy |
|
PDF (Bab VI)
BAB 6.pdf Restricted to Repository staff only Download (9kB) | Request a copy |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (7kB) |
|
PDF (Lampiran)
LAMPIRAN-LAMPIRAN.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (Pernyataan Publikasi Ilmiah)
pernyataan publikasi ilmiah.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Designing the footing should consider the bearing capacity of the soil below it. Clay have low bearing capacity because of its character which is it will be solid when on dry condition and become plastic when the moisure content is high. Skirted footing is one of the alternatives that can be used to increase the bearing capacity and reduce the settlement of footings on soil. This research presented the result of the bearing capacity test on skirt footings and without skirt on clay. There are variations in testing’s many as 9 steel foundation sample, there are, L/B 0 (0/75); 0 (0/100); 0 (0/150); 0,67 (100/150); 1,00 (150/150); 1,00 (100/100); 1,33 (100/75); 1,50 (150/100) and 2,00 (150/75). Water content in the clays is conditioned by 15% for each test with 100 times of compaction for every layers. From the result of loading test, it can be known that skirted footing got bigger bearing capacity than footing without skirt. Besides that, the skirt effectively reduce the settlement happens reviewed by the load of 1 kN. The wider and longer of the skirt footing, make the bearing capacity increased and the settlement progressively smaller. It also noted that on the condition when the width and the diameter are same, the settlements on square footing are smaller than rounded one.
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | clays, loading test, settlement, skirted footing, |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Fakultas Teknik > Teknik Sipil |
Depositing User: | FAJAR KURNIAWAN |
Date Deposited: | 27 Dec 2017 03:42 |
Last Modified: | 27 Dec 2017 03:42 |
URI: | http://eprints.ums.ac.id/id/eprint/57770 |