Penatalaksanaan Fisioterapi Pada Kasus Paska Operasi Fraktur Tibia-Fibula 1/3 Distal Sinistra Dengan External Fixator Unilateral Frame Di Rumah Sakit Orthopedi Prof.Dr Soeharso Surakarta

Noviyana, Ulfa and , Isnaini Herawati, S.Fis., S.Pd., M.Sc (2016) Penatalaksanaan Fisioterapi Pada Kasus Paska Operasi Fraktur Tibia-Fibula 1/3 Distal Sinistra Dengan External Fixator Unilateral Frame Di Rumah Sakit Orthopedi Prof.Dr Soeharso Surakarta. Diploma thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (NASKAH PUBLIKASI)
NASKAH PUBLIKASI.pdf

Download (489kB)
[img] PDF (HALAMAN DEPAN)
HALAMAN DEPAN.pdf

Download (379kB)
[img] PDF (BAB I)
BAB I.pdf

Download (199kB)
[img] PDF (BAB II)
BAB II.pdf
Restricted to Repository staff only

Download (217kB) | Request a copy
[img] PDF (BAB III)
BAB III.pdf
Restricted to Repository staff only

Download (291kB) | Request a copy
[img] PDF (BAB IV)
BAB IV.pdf
Restricted to Repository staff only

Download (206kB) | Request a copy
[img] PDF (BAB V)
BAB V.pdf
Restricted to Repository staff only

Download (86kB) | Request a copy
[img] PDF (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf

Download (185kB)
[img] PDF (LAMPIRAN)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (PERNYATAAN PUBLIKASI)
PERNYATAAN PUBLIKASI.pdf
Restricted to Repository staff only

Download (75kB) | Request a copy

Abstract

Background: Post OREF fraktur cruris 1/3 distal sinistra is kind of surgery to of moutingan external fixasi conducted on the tibia one-third distal part distal next to the left. Physiotherapy in this case reduce pain, lower odema, add Range of motion, and improve the ability of the functional with therapy exercise. Purpose: to know the influence of therapy exercise against a decrease in the pain, the declines odema, increase range of motion and increasing the activity of the funcional walked on the post fraktur tibia-fibula one-third distal sinistra with eksternal fixator unilateral frame. Results: After therapy for about four times the obtained result of the assesment of motion pain T0: 4,3cm to T4: 1,1cm, pressure pain T0: 6,2cm to T4: 5cm and motion pain T0:6,4cm to T4: 4,2cm. Reduce odema with the difference condylus T0: 1,6cm to T4: 0,7cm, distal ofcondylus 5cm T0: 2,5cm to T4: 1,5cm, distal of condylus 10cm T0: 2,5cm to T4: 1,7cm, proksimal of condylus 5 cm T0= 0,4cm to T4: 0,2cm, proksimal of condylus 10cm T0= 0,7cm to T4: 0,4cm, maleolus medialis: T0= 1,7cm to T4: 1cm. Increase active range of motion knee joint T0: S= 0-0-50 to T4: S= 0-0-95, passive range of motion knee joint T0:S= 0-0-60 to T4:S= 0-0-135, active range of motion ankle joint T0: S= S= 0-0-5 to T4:S= 0-0-35, passive range of motion ankle joint T0: S= S= 0-0-5to T4:S= 0-0-45. Cunclution: Therapy exercise can reduce pain, reduce odema, improve range of motion and increasing the activity of the functional knee surgery on the post fraktur cruris one-third distal with fixator extenal.

Item Type: Karya ilmiah (Diploma)
Uncontrolled Keywords: Fraktur cruris, open reduction external fixator (OREF), therapy exercise.
Subjects: R Medicine > RM Therapeutics. Pharmacology
Divisions: Fakultas Ilmu Kesehatan > Fisioterapi D3
Depositing User: ULFA NOVIYANA
Date Deposited: 06 Aug 2016 05:04
Last Modified: 06 Aug 2016 05:04
URI: http://eprints.ums.ac.id/id/eprint/45065

Actions (login required)

View Item View Item