Nugroho, Ahmad Rizal Bayu and , Agus Widodo, S.Fis, M.Fis (2015) Penatalaksanaan Fisioterapi Pada Kasus Post Pemasangan Open Reduction Internal Fixation Fraktur 1/3 Distal Humerus Sinistra Di RSUD Panembahan Senopati Bantul. Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
11. NASKAH PUBLIKASI.pdf Download (346kB) |
|
PDF (Halaman Depan)
02. HALAMAN DEPAN..pdf Download (331kB) |
|
PDF (Bab I)
03. BAB I.pdf Download (162kB) |
|
PDF (Bab II)
04. BAB II.pdf Restricted to Repository staff only Download (419kB) |
|
PDF (Bab III)
05. BAB III.pdf Restricted to Repository staff only Download (228kB) |
|
PDF (Bab IV)
06. BAB IV.pdf Restricted to Repository staff only Download (278kB) |
|
PDF (Bab V)
07. BAB V.pdf Download (152kB) |
|
PDF (Daftar Pustaka)
08. DAFTAR PUSTAKA.pdf Download (81kB) |
|
PDF (Lampiran)
09. LAMPIRAN.pdf Restricted to Repository staff only Download (324kB) |
|
PDF (Surat Pernyataan Publikasi)
01. SURAT PERNYATAAN PUBLIKASI.pdf Restricted to Repository staff only Download (133kB) |
Abstract
Background : 1/3 distal humeral fracture is a fracture that occurs in the middle third and suprakondiler, Events fracture can cause pain conditions, limitations ROM, edema, decreased muscle strength due to pain and functional impairment. Objective : To determine the benefits of Infrared, and Exercise to reduce pain , decrease edema , increase range of motion ( ROM ) , improve muscle strength , and improve functional ability. Results : From the results of therapy can be concluded that the decrease in VAS pain from T0 to T6 treatment can be seen, silent pain T0 ( value 3.4 ) and T6 ( value 0 ), whereas tenderness at T0 ( value 3.7 ) and T6 ( value of 0 ), and Pain Motion of T0 ( value 6.3 ) and T6 ( value 1.8 ). Edema measured by mideline of lateral epicondylus 6 cm proximal to T0 ( 26 cm ) and T6 ( value 24.5 cm ), lateral epicondylus 6 cm distal to T0 ( value 23.5 cm ) and T6 ( value 23.5 cm ), are to epicondylus 12 cm lateral to the proximal T0 (value 27 cm ), and T6 ( value 26 cm ) and 12 cm lateral to epicondylus distally from T0 to T6 ( value 21.7 cm ) LGS with Goneometer actively from T0 ( S = 00-150-750 ) and T6 ( S = 00-00- 1300 ), while for passive motion T0 ( S = 00-50-800 ) and T6 ( S = 00-00 -1400). Muscle strength in elbow Sinestra T0 ( values to 3- ) and T6 ( value 4 ). As for the functional ability of the index woodstock Rehab & Fitness at the elbow with the results obtained T0 therapy ( value 20.5 ) with a description of the worst pain / very heavy during the move, and at T6 ( value 7.5 ) with a description of a light but constant pain when to move. Conclusion : Infrared can reduce pain , edema , moderate exercise therapy can improve muscle strength , increase range of motion ( LGS ) , and improve functional activities .
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | Fracture of the humerus , Infrared , Therapeutic exercise |
Subjects: | R Medicine > R Medicine (General) R Medicine > RM Therapeutics. Pharmacology |
Divisions: | Fakultas Ilmu Kesehatan > Fisioterapi D3 |
Depositing User: | Cahyana K. Widada |
Date Deposited: | 27 Nov 2015 02:05 |
Last Modified: | 11 Oct 2021 02:13 |
URI: | http://eprints.ums.ac.id/id/eprint/39648 |
Actions (login required)
View Item |