Pengaruh Durasi Aplikasi Bahan Adhesif Self-Etch Terhadap Kebocoran Mikro pada Tumpatan Resin Komposit Kelas V

Hapsari, Rani Indri and , drg. Noor Hafida Widyastuti, Sp.KG and , drg. Nanang Krisnawan (2015) Pengaruh Durasi Aplikasi Bahan Adhesif Self-Etch Terhadap Kebocoran Mikro pada Tumpatan Resin Komposit Kelas V. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
NASKAH PUBLIIKASI.pdf

Download (499kB)
[img] PDF (Halaman Depan)
HALAMAN DEPAN.pdf

Download (1MB)
[img] PDF (Bab I)
BAB I.pdf

Download (99kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (412kB)
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (625kB)
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (31kB)
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (7kB)
[img] PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (126kB)
[img] PDF (Lampiran)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (1MB)
[img] PDF (Surat Pernyataan Publikasi)
SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf
Restricted to Repository staff only

Download (360kB)

Abstract

Microleakage was one of the major concerns associated with composite restoration. One of the ways to prevent microleakage was prolonged self-etch adhesive application time. The aim of this study was to evaluate the effect of selfetch adhesive application time on microleakage class V composite restoration. This research was a laboratory experimental study using posttest only control group design. 27 premolar teeth were prepared for class V cavity and were divided into 3 self-etch adhesive application time groups: group I (20 seconds), group 30 (30 seconds), and group III (40 seconds), then cured by light curing and the cavities were restored with composite resin. Specimens were thermocycled, immersed in methylene blue 2% then centrifuged. Teeth were sectioned and evaluated using a stereomicroscope at 120x magnification. Statistical analysis was performed with Kruskal-Wallis (p<0,05) and Mann-Whitney test. The results showed that there was no significant different between group I & II. Significant difference was seen between group II&III and group I&III. Conclusion: self-etch adhesive application time had effect on microleakage class V composite restoration.

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: Self-Etch, Microleakage, Application Time
Subjects: R Medicine > RK Dentistry
Divisions: Fakultas Kedokteran Gigi > Kedokteran Gigi
Depositing User: Cahyana K. Widada
Date Deposited: 13 Nov 2015 02:37
Last Modified: 12 Oct 2021 16:42
URI: http://eprints.ums.ac.id/id/eprint/39423

Actions (login required)

View Item View Item