Hapsari, Rani Indri and , drg. Noor Hafida Widyastuti, Sp.KG and , drg. Nanang Krisnawan (2015) Pengaruh Durasi Aplikasi Bahan Adhesif Self-Etch Terhadap Kebocoran Mikro pada Tumpatan Resin Komposit Kelas V. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIIKASI.pdf Download (499kB) |
|
PDF (Halaman Depan)
HALAMAN DEPAN.pdf Download (1MB) |
|
PDF (Bab I)
BAB I.pdf Download (99kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (412kB) |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (625kB) |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (31kB) |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (7kB) |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (126kB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (1MB) |
|
PDF (Surat Pernyataan Publikasi)
SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf Restricted to Repository staff only Download (360kB) |
Abstract
Microleakage was one of the major concerns associated with composite restoration. One of the ways to prevent microleakage was prolonged self-etch adhesive application time. The aim of this study was to evaluate the effect of selfetch adhesive application time on microleakage class V composite restoration. This research was a laboratory experimental study using posttest only control group design. 27 premolar teeth were prepared for class V cavity and were divided into 3 self-etch adhesive application time groups: group I (20 seconds), group 30 (30 seconds), and group III (40 seconds), then cured by light curing and the cavities were restored with composite resin. Specimens were thermocycled, immersed in methylene blue 2% then centrifuged. Teeth were sectioned and evaluated using a stereomicroscope at 120x magnification. Statistical analysis was performed with Kruskal-Wallis (p<0,05) and Mann-Whitney test. The results showed that there was no significant different between group I & II. Significant difference was seen between group II&III and group I&III. Conclusion: self-etch adhesive application time had effect on microleakage class V composite restoration.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | Self-Etch, Microleakage, Application Time |
Subjects: | R Medicine > RK Dentistry |
Divisions: | Fakultas Kedokteran Gigi > Kedokteran Gigi |
Depositing User: | Cahyana K. Widada |
Date Deposited: | 13 Nov 2015 02:37 |
Last Modified: | 12 Oct 2021 16:42 |
URI: | http://eprints.ums.ac.id/id/eprint/39423 |
Actions (login required)
View Item |