Roesiani, Lina and , Haru Subaris Kasjono, SKM., M. Kes and , Dwi Astuti, SKM., M.Kes (2015) Keefektifan Lama Kontak Karbon Aktif Terhadap Penurunan Kadar Amonia Limbah Cair Industri Tahudi Desa Teguhan Sragen Wetan Sragen. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (NASKAH PUBLIKASI)
Naskah Publikasi.pdf Download (542kB) |
|
PDF (HALAMAN DEPAN)
cover new.pdf Download (1MB) |
|
PDF (BAB I)
BAB I.pdf Download (170kB) |
|
PDF (BAB II)
BAB II.pdf Restricted to Repository staff only Download (219kB) |
|
PDF (BAB III)
BAB III.pdf Restricted to Repository staff only Download (201kB) |
|
PDF (BAB IV)
lina IV.pdf Restricted to Repository staff only Download (215kB) |
|
PDF (BAB V)
BAB V.pdf Restricted to Repository staff only Download (184kB) |
|
PDF (BAB VI)
BAB VI.pdf Restricted to Repository staff only Download (87kB) |
|
PDF (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf Download (10kB) |
|
PDF (LAMPIRAN)
Lampiran.pdf Restricted to Repository staff only Download (2MB) |
|
PDF (PERNYATAAN PUBLIKASI ILMIAH)
Surat Pernyataan Publikasi.pdf Restricted to Repository staff only Download (155kB) |
Abstract
Tofu Liquid Waste has smell that comes from the content of ammonia in it. The measurement result of tofu liquid waste in Teguhan of SragenWetan Village, Sragen districts has known that levels of ammonia is 30,6 mg/l so does not fulfill for a quality standard.The purpose of this research to determine contact timeofactived carbon that the most effective to reduce ammonia levels in tofu liquid waste with variations contact time of actived carbon 0 minutes (control), 3 minutes, 5 minutes, and 7 minutes. The methods of this research is an experimental study with a pretest-posttest design with control group. The population for this research are37 tofu industries and the techniques sampling using purposive sampling. The statistical test using One Way Anova with results of the analysis data obtained p value = 0.000 (<0.01), therefore it concluded that the contact time of actived carbon are the most effective to reduce levels of ammonia. In Post Hoc Test, known that contact 7 minutes had mean difference 4,16667, it means the contact 7 minutes has the highest a different value than contact 3 minutes and 5 minutes, this value indicates that the contact 7 minutes is the most effective time to reduce levels of ammonia to be 19,93 mg/l and fulfill for a quality standard.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | Tofu Liquid Waste, Ammonia, Actived Carbon |
Subjects: | R Medicine > R Medicine (General) |
Divisions: | Fakultas Ilmu Kesehatan > Kesehatan Masyarakat |
Depositing User: | Unnamed user with username j410100098 |
Date Deposited: | 03 Nov 2015 09:05 |
Last Modified: | 11 Oct 2021 01:43 |
URI: | http://eprints.ums.ac.id/id/eprint/38910 |
Actions (login required)
View Item |