Haris, Firza Imammul and , Agus Supardi, S.T., M.T. (2024) Rancang Bangun Alat Monitoring PLTS Off Grid Berbasis Internet of Things (IoT) Menggunakan Blynk. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf Download (885kB) |
|
PDF (Halaman Depan)
HALAMAN DEPAN.pdf Download (395kB) |
|
PDF (Bab I)
BAB 1.pdf Download (131kB) |
|
PDF (Bab II)
BAB 2.pdf Restricted to Repository staff only Download (727kB) |
|
PDF (Bab III)
BAB 3.pdf Restricted to Repository staff only Download (698kB) |
|
PDF (Bab IV)
BAB 4.pdf Restricted to Repository staff only Download (270kB) |
|
PDF (Bab V)
BAB 5.pdf Restricted to Repository staff only Download (170kB) |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (171kB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (179kB) |
|
PDF (Surat Pernyataan Publikasi)
SURAT PERNYATAAN PUBLIKASI.pdf Restricted to Repository staff only Download (337kB) |
Abstract
One way of utilizing sunlight is by using PLTS. PLTS can convert sunlight energy into electrical energy by absorbing photons through photovoltaic cells in solar panels. The amount of electrical energy produced from solar panels can of course change depending on the amount of light absorbed by the panels. Apart from that, the amount of electrical energy produced by solar panels is influenced by the conditions of the surrounding environment, including exposure to dirt which can be in the form of dust or other things, so it needs to be monitored continuously. This research will focus on a monitoring system with the help of the Blynk platform as a tool for monitoring output data on PLTS, namely current, voltage, power, temperature, and humidity. This test aims to compare the results of manual measurements with the results of monitoring using the INA219 sensor, PZEM-004T sensor, and DHT11 sensor as comparison objects. The results of tests carried out over two days showed different error values. The test results on the solar panels showed that the average current error value was 1%, while the average voltage error value was 2.5%. The test results on the inverter output showed an average current error value of 2.3%, an average voltage error value of 0.52%, and an average frequency error value of 0.3%.
Item Type: | Thesis (Skripsi) |
---|---|
Uncontrolled Keywords: | Blynk, Internet of Things, Monitoring, PLTS |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK01 Weak flow |
Divisions: | Fakultas Teknik > Teknik Elektro |
Depositing User: | FIRZA IMAMMUL HARIS |
Date Deposited: | 12 Feb 2024 02:28 |
Last Modified: | 12 Feb 2024 02:28 |
URI: | http://eprints.ums.ac.id/id/eprint/121787 |