Perbandingan Kekasaran Dan Kekerasan Permukaan Besi Cor Kelabu Sebelum dan Sesudah Pelapisan Nikel-Krom dengan Metode Elektroplating

Shoberi, Muhamad Aji and -, Dr. Agus Yulianto, S.T., M.T. (2023) Perbandingan Kekasaran Dan Kekerasan Permukaan Besi Cor Kelabu Sebelum dan Sesudah Pelapisan Nikel-Krom dengan Metode Elektroplating. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
Naskah Publikasi.pdf

Download (876kB)
[img] PDF (Bab I)
Bab I.pdf

Download (226kB)
[img] PDF (Bab II)
Bab II.pdf
Restricted to Repository staff only

Download (496kB) | Request a copy
[img] PDF (Bab III)
Bab III.pdf
Restricted to Repository staff only

Download (777kB) | Request a copy
[img] PDF (Bab IV)
Bab IV.pdf
Restricted to Repository staff only

Download (328kB) | Request a copy
[img] PDF (Bab V)
Bab V.pdf
Restricted to Repository staff only

Download (218kB) | Request a copy
[img] PDF (Surat Pernyataan Publikasi)
Surat Pernyataan Publikasi.pdf
Restricted to Repository staff only

Download (473kB) | Request a copy
[img] PDF (Daftar Pustaka)
Daftar Pustaka.pdf

Download (531kB)
[img] PDF (Halaman Depan)
Halaman Depan.pdf

Download (1MB)
[img] PDF (Lampiran)
Lampiran.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

Electroplating is a process of electrolytically deposition of protective metal ions (anode), which is desired on top of another metal (cathode). This study aims to analyze the roughness value and surface hardness value of gray cast iron before and after nickel-chrome plating by electroplating method. Roughness testing is carried out using the Surface Roughness Tester to determine the roughness value, while the hardness test is carried out using the Rockwell Hardness Tester method to determine the hardness value. The results obtained from surface roughness testing are on specimens without coating (raw material) have a higher roughness value compared to the roughness value on specimens that have been coated with nickel 90 minutes & chrome 20 seconds, with a roughness value of 4.504875 μm. While in specimens that have been coated, only an average roughness value of 1.17975 μm was obtained. The results obtained from Rockwell hardness testing are that specimens that have been coated with nickel 90 minutes & chrome 20 seconds have a higher hardness value compared to specimens without coating (raw material), the average value of hardness in coated specimens is 87.9 HRB. While the average value of hardness in specimens without coating (raw material) is 84.33 HRB.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: gray cor iron, electroplating, chrome, roughness, hardness
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: MUHAMAD AJI SHOBERI
Date Deposited: 22 Nov 2023 06:57
Last Modified: 22 Nov 2023 06:57
URI: http://eprints.ums.ac.id/id/eprint/118835