Pengaruh Ion Implantasi Nitrogen Terhadap Senyawa yang Terbentuk, Kekerasan dan Ketahanan Aus pada Permukaan Titanium Murni Komersial

Priyono, Nanang and -, Agung Setyo Darmawan, ST. MT (2019) Pengaruh Ion Implantasi Nitrogen Terhadap Senyawa yang Terbentuk, Kekerasan dan Ketahanan Aus pada Permukaan Titanium Murni Komersial. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf

Download (1MB)
[img] PDF (Halaman Depan)
HALAMAN DEPAN.pdf

Download (1MB)
[img] PDF (Bab I)
BAB I.pdf

Download (120kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (506kB) | Request a copy
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (603kB) | Request a copy
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (9kB) | Request a copy
[img] PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (198kB)
[img] PDF (Lampiran)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (593kB) | Request a copy
[img] PDF (Surat Pernyataan Publikasi Karya Ilmiah)
SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf
Restricted to Repository staff only

Download (218kB) | Request a copy

Abstract

This study aim to determine the effect of time on the compounds formed hardness and wear resistance on the surface of commercially pure titanium. This research was conducted with a time variation of 60, 75, 90, 105, 120 minutes with a voltage of 60 keV and a current of 100 Ma. After ion implantation process XRP testing, hardness and wear resistance are tested. From the test result, the initial hardness value of 105, 75 VHN with the optimum ion implantation process for 90 minutes increased to 170,6 VHN. While the hardness of the cross-section point closest to the surface has a hardness that is almost the same as the surface and has a decrease in hardness at the point bellow. At the initial wear test of 4,0148 x 10-8 mm2/kg a decrease of 1,78 x 10-9 mm2/kg. These changes occur due to the formation of TiN compounds on the surface of commercially pure titanium after ion processing has been processed.

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: ion, implantasi, titanium, senyawa
Subjects: T Technology > TJ Mechanical engineering and machinery
T Technology > TN Mining engineering. Metallurgy
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: NANANG PRIYONO
Date Deposited: 12 Nov 2019 01:41
Last Modified: 19 Nov 2019 07:00
URI: http://eprints.ums.ac.id/id/eprint/78421