Falah, Muhammad Fajril and , Wijianto, S.T., M.Eng.Sc. (2018) Analisis Hasil Gasifikasi Sekam Padi Dengan Variasi Kecepatan Udara Primer Dan Penambahan Udara Sekunder Pada Tungku Gasifikasi Up Draft Tipe Kontinu. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf Download (1MB) |
|
PDF (Halaman Depan)
Halaman Depan.pdf Download (1MB) |
|
PDF (Bab I)
BAB I.pdf Download (50kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (197kB) | Request a copy |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (417kB) | Request a copy |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (385kB) | Request a copy |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (61kB) | Request a copy |
|
PDF (Daftar Pustaka)
Daftar Pustaka.pdf Download (90kB) |
|
PDF (Surat Pernyataan Publikasi Ilmiah)
Surat Pernyataan Publikasi Karya Ilmiah.pdf Restricted to Repository staff only Download (248kB) | Request a copy |
|
PDF (Lampiran)
Lampiran-125.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
One of the biomass energy utilization is with the use of Up Draft gasification stove. Variations in primary air and on the reactor wall are one of the development of cooking design of Up Draft gasification cooking used on the stove in this study. The purpose of this study was to know flame temperature, effective flame time, and calculate the thermal efficiency of Up Draft gasification stove with different variations of primary air and reactor wall. The test is carried out by taking flame temperature data and boiling temperature of water every 30 seconds on the variation of primary air flow velocity (6 m/s, 8 m/s, 10 m/s) without air addition and with the addition of 2 m/s, 3 m/s, 4 m/s on the wall of the cooker reactor gasification Up Draft. The total operating time is recorded on each test. The results of this study indicate that the highest average flame temperatures are obtained on the primary airflow velocity variation of 10 m / s without the addition of air to the reactor wall. The best thermal efficiency was obtained at testing the variation of the primary airflow velocity of 10 m / s without the addition of air to the reactor wall.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | Gasifikasi, Tungku Gasifikasi Up Draft, Sekam Padi, Variasi Udara |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | MUHAMMAD FAJRIL FALAH |
Date Deposited: | 23 Feb 2018 07:06 |
Last Modified: | 23 Feb 2018 07:06 |
URI: | http://eprints.ums.ac.id/id/eprint/60456 |