Mustofa, Budi and , Hasyim Asy'ari, ST., MT (2017) Perancangan Instalasi Listrik Gedung Rumah Sakit Alisha Rahman Sejahtera Karawang. Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (SURAT PERNYATAAN PUBLIKASI)
SURAT PERNYATAAN PUBLIKASI ILMIAH.pdf Download (272kB) |
|
PDF (NASKAH PUBLIKASI)
TA MEP RS Alisha Rahman Sejahtera Karawang1.pdf Download (1MB) |
Abstract
Building Prosperity Karawang Rs Alisha Rahman is the building that served as a public service in the field of health for the general population should be a good support facilities for users. In order to meet the needs of health facilities, medicine, waiters, and building user comfort can not be separated from the electrical energy needs, especially on the installation of lighting, electrical outlets, air conditioning (Air Conditioner), water pumps, fire pumps, and elevators. The installation of a good electrical installation, correct and safe in operation will add a sense of comfort, quiet, and safe for users of the building. in order to meet these needs then be made to the design of electrical installation calculation is correct, reliable well as an economical price, as well as the determination of clean water and dirty water. Installation design that aims to design the need for mechanical electrical installation in Alisha Rahman Sejahtera Hospital building. The method used to determine the load capacity of clean water and dirty water in the installation using manual calculation, the space factor, the factor, the factor of the building as a parameter. Meanwhile, to determine the main safety measure, the conductor diameter and the amount of power requirement refers to the planned calculation. Results of calculations designed indicates total apparent power (S) needed sebessar 244109,5813 VA / 244.109581 kVA using the ultimate safety MCCB (Molded Case Circuit Breaker) with a capacity of 3 phase 552a and using main conductive NYY 4 x 1 x 300 mm2 conductance capability currents up to 580 A, and the capacity of 1524.45 m3 Groundtank with a size of 15 x 13 x 8m, and Rooftank capacity of 33 m3 with size of 35000 liters.
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | Electricity Installation, Main safety, AutoCAD |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Fakultas Teknik > Teknik Elektro |
Depositing User: | BUDI MUSTOFA |
Date Deposited: | 03 Aug 2017 04:15 |
Last Modified: | 03 Aug 2017 04:18 |
URI: | http://eprints.ums.ac.id/id/eprint/54384 |
Actions (login required)
View Item |