Keefektifan Em-4 (Effective Microorganism-4) Dalam Menurunkan Chemical Oxygen Demand (Cod) Limbah Cair Industri Batik

Ramlan, Muh and , Dwi Astuti, M. Kes. (2017) Keefektifan Em-4 (Effective Microorganism-4) Dalam Menurunkan Chemical Oxygen Demand (Cod) Limbah Cair Industri Batik. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
NASKAH PUBLIKASI.pdf

Download (624kB)
[img] PDF (Halaman Depan)
HALAMAN DEPAN NEW.pdf

Download (1MB)
[img] PDF (Bab I)
BAB I.pdf

Download (62kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (160kB) | Request a copy
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (233kB) | Request a copy
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (77kB) | Request a copy
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (134kB) | Request a copy
[img] PDF (Bab VI)
BAB VI.pdf
Restricted to Repository staff only

Download (128kB) | Request a copy
[img] PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (54kB)
[img] PDF (Lampiran)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (6MB) | Request a copy
[img] PDF (Surat Pernyataan Publikasi Ilmiah)
SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf

Download (528kB)

Abstract

Based on the results of examination of COD in industrial waste water Nggemblegan Village sub district Kalikotes batik Klaten exceeds standard quality raw wastewater Perda Jateng No. 5 in 2012 that is 482.5 mg/l. purpose of this research is to analyse the effectiveness of EM-4 in lowering levels of COD of waste liquid batik industry. Experimental method used with pretest-posttest design with control group. The number of samples used is 12 litres, each treatment takes 1 liter of waste with 3 repetitions. The results of the laboratory test on the levels of COD, controls an average of 447.3 mg/l, and in the treatment group 1 ml/l, 2 l, and ml/3 ml/l COD levels an average of 393.2 mg/l, 302.6/l, mg 280.2 mg/l. dose effect on the decline of COD in the dose of 3 ml/l of 72,5%. The results of the anova statistical test shows (p < 0.01) there is the influence of the EM-4 against a decline in the levels of COD of waste batik.

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: COD, Batik, liquid waste EM-4
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine