Murdiono, Gilang and , Wijianto, ST., M.Eng.Sc. (2017) Pengaruh Variasi Pemanasan Awal Udara dan Penambahan Udara Bantu Pada Reaktor Terhadap Performa Kompor Gasifikasi Sekam Padi Top Lit Up Draft (TLUD). Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
09 NASKAH PUBLIKASI.pdf Download (998kB) |
|
PDF (Halaman Depan)
01 HALAMAN AWAL.pdf Download (893kB) |
|
PDF (Bab I)
02 BAB I.pdf Download (160kB) |
|
PDF (Bab II)
03 BAB II.pdf Restricted to Repository staff only Download (384kB) | Request a copy |
|
PDF (Bab III)
04 BAB III.pdf Restricted to Repository staff only Download (458kB) | Request a copy |
|
PDF (Bab IV)
05 BAB IV.pdf Restricted to Repository staff only Download (596kB) | Request a copy |
|
PDF (Bab V)
06 BAB V.pdf Restricted to Repository staff only Download (88kB) | Request a copy |
|
PDF (Daftar Pustaka)
07 DAFTAR PUSTAKA.pdf Download (11kB) |
|
PDF (Lampiran)
08 LAMPIRAN.pdf Restricted to Repository staff only Download (809kB) | Request a copy |
|
PDF (Pernyataan Publikasi Ilmiah)
10 SURAT PERNYATAAN.pdf Restricted to Repository staff only Download (322kB) | Request a copy |
Abstract
Abstact One of technology that using gasification is top lit up draft gasification stove.the objective of this study is to know the effect of variation inlet air heating and air addition on reactor toward perfomance of top lit up draft gasification stove. This study using top lit up draft gasification stove with 2 methods of test with air addition on reactor and test with no air addition on reactor every test have variation of begin air temperature and air velocity. Begin air temperature that use is 320C,500C,700C and every temperature test with 8 m/s,10m/s, 12m/s and then measuring combustion temperature, water temperature, and effectiveness burning. The result of this study shown high value of begin air temperature and with air addition on reactor then high value too the combustion temperature and short time effectiveness burning produces the result same when adding air on reactor, the best thermal efficiency get 500C begin air temperature with 10m/s air velocity thermal efficiency is about 15,958 %.
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | Gasifikasi, Top Lit Up Draft, Pemanasan awal udara, Sekam Padi |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | GILANG MURDIONO |
Date Deposited: | 04 Apr 2017 01:52 |
Last Modified: | 04 Apr 2017 01:52 |
URI: | http://eprints.ums.ac.id/id/eprint/50714 |
Actions (login required)
View Item |