Sulistyo, Dhevid and , Ir. Ali Asroni, MT (2016) Perancangan Gedung Hotel 4 lantai di Daerah Solo Baru, Sukoharjo dengan Sistem Rangka Pemikul Momen Menengah. Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
Naskah Publikasi.pdf Download (930kB) |
|
PDF (Halaman Depan)
HALAMAN DEPAN.pdf Download (1MB) |
|
PDF (Bab I)
BAB I.pdf Download (165kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (306kB) |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (708kB) |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (372kB) |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (632kB) |
|
PDF (Bab VI)
BAB VI.pdf Restricted to Repository staff only Download (7MB) |
|
PDF (Bab VII)
BAB VII.pdf Restricted to Repository staff only Download (11MB) |
|
PDF (Bab VIII)
BAB VIII.pdf Restricted to Repository staff only Download (580kB) |
|
PDF (Bab IX)
BAB IX.pdf Restricted to Repository staff only Download (114kB) |
|
PDF (Daftar Pustaka)
Daftar pustaka.pdf Download (57kB) |
|
PDF (Lampiran)
LAMPIRAN.pdf Restricted to Repository staff only Download (5MB) |
|
PDF (Pernyataan Publikasi Ilmiah)
Surat Pernyataan.pdf Restricted to Repository staff only Download (2MB) |
Abstract
Sukoharjo regency is one of the growing areas in terms of economy and tourism. With respect to the development of the supporting infrastructure requires to meet the needs of temporary accommodation of travellers, the hotel is one of the solutions to meet those needs. The purpose of this final task is to plan the structure of the building 4 floor frame system with Secondary Moment Resisiting Frame (SMRF) in the area of Sukoharjo. Planning the structure refers to the SNI 1726-2012 (the rules of building structure earthquake for building structure and non-structure) and the SNI 2847-2013 (requirenment of concrete structural for building structure). Data planning includes land site classification categories SC (the ground hard), earthquake resistant building with response modification factor (R) by virtue of building factor 5, Ie with a value of 1.0. The quality of concrete used f'c 25 MPa, as well as longitudinal reinforcement fy = 350 MPa and shear reinforcement (begel) fyt = 320 MPa. Calculating the forces within SAP applications using SAP2000 and to draw the results of calculations using the AutoCAD application. The results of the calculation produces a thick 12 cm for floor slab and roof slabs with a thickness of 10 cm and 15 cm. For the main structure of the beams were obtained with dimensions 300/400 and column with dimensions 300/400, for bottom structure using continuous foundation and sloof with dimensions 400/1000 with soil bearing capacity = 125 kPa at a depth of -2.0 m.
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | planning, secondary moment resisiting frame, building structure, SAP 2000. |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Fakultas Teknik > Teknik Sipil |
Depositing User: | DHEVID SULISTYO |
Date Deposited: | 30 Jan 2017 02:33 |
Last Modified: | 30 Jan 2017 02:33 |
URI: | http://eprints.ums.ac.id/id/eprint/48580 |
Actions (login required)
View Item |