Perancangan Gedung Hotel 4 lantai di Daerah Solo Baru, Sukoharjo dengan Sistem Rangka Pemikul Momen Menengah

Sulistyo, Dhevid and , Ir. Ali Asroni, MT (2016) Perancangan Gedung Hotel 4 lantai di Daerah Solo Baru, Sukoharjo dengan Sistem Rangka Pemikul Momen Menengah. Diploma thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
Naskah Publikasi.pdf

Download (930kB)
[img] PDF (Halaman Depan)
HALAMAN DEPAN.pdf

Download (1MB)
[img] PDF (Bab I)
BAB I.pdf

Download (165kB)
[img] PDF (Bab II)
BAB II.pdf
Restricted to Repository staff only

Download (306kB)
[img] PDF (Bab III)
BAB III.pdf
Restricted to Repository staff only

Download (708kB)
[img] PDF (Bab IV)
BAB IV.pdf
Restricted to Repository staff only

Download (372kB)
[img] PDF (Bab V)
BAB V.pdf
Restricted to Repository staff only

Download (632kB)
[img] PDF (Bab VI)
BAB VI.pdf
Restricted to Repository staff only

Download (7MB)
[img] PDF (Bab VII)
BAB VII.pdf
Restricted to Repository staff only

Download (11MB)
[img] PDF (Bab VIII)
BAB VIII.pdf
Restricted to Repository staff only

Download (580kB)
[img] PDF (Bab IX)
BAB IX.pdf
Restricted to Repository staff only

Download (114kB)
[img] PDF (Daftar Pustaka)
Daftar pustaka.pdf

Download (57kB)
[img] PDF (Lampiran)
LAMPIRAN.pdf
Restricted to Repository staff only

Download (5MB)
[img] PDF (Pernyataan Publikasi Ilmiah)
Surat Pernyataan.pdf
Restricted to Repository staff only

Download (2MB)

Abstract

Sukoharjo regency is one of the growing areas in terms of economy and tourism. With respect to the development of the supporting infrastructure requires to meet the needs of temporary accommodation of travellers, the hotel is one of the solutions to meet those needs. The purpose of this final task is to plan the structure of the building 4 floor frame system with Secondary Moment Resisiting Frame (SMRF) in the area of Sukoharjo. Planning the structure refers to the SNI 1726-2012 (the rules of building structure earthquake for building structure and non-structure) and the SNI 2847-2013 (requirenment of concrete structural for building structure). Data planning includes land site classification categories SC (the ground hard), earthquake resistant building with response modification factor (R) by virtue of building factor 5, Ie with a value of 1.0. The quality of concrete used f'c 25 MPa, as well as longitudinal reinforcement fy = 350 MPa and shear reinforcement (begel) fyt = 320 MPa. Calculating the forces within SAP applications using SAP2000 and to draw the results of calculations using the AutoCAD application. The results of the calculation produces a thick 12 cm for floor slab and roof slabs with a thickness of 10 cm and 15 cm. For the main structure of the beams were obtained with dimensions 300/400 and column with dimensions 300/400, for bottom structure using continuous foundation and sloof with dimensions 400/1000 with soil bearing capacity = 125 kPa at a depth of -2.0 m.

Item Type: Karya ilmiah (Diploma)
Uncontrolled Keywords: planning, secondary moment resisiting frame, building structure, SAP 2000.