Nanda, Riski Yoga and , Ir. H. Sarjito, MT., Ph.D. (2016) Uji Karakteristik Hipotesis Bangunan Rumah Tinggal yang Memanfaatkan Pendinginan Evaporasi dengan Computational Fluids Dynamics (CFD). Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
naspub fixx.pdf Download (2MB) |
|
PDF (Halaman Depan)
HALAMAN AWAL.pdf Download (906kB) |
|
PDF (Bab I)
BAB I.pdf Download (275kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (884kB) | Request a copy |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (943kB) | Request a copy |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (106kB) | Request a copy |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (88kB) |
|
PDF (Lampiran)
Lampiran.pdf Restricted to Repository staff only Download (874kB) | Request a copy |
|
PDF (Pernyataan Publikasi Ilmiah)
PERNYATAAN PUBLIKASI ILMIAH PERPUS.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Air conditioning in housing is required to obtain thermal comfort zone, especially at urban areas that have problems with the limitations of land. One of alternative room air conditioning (AC) that environmently-friendly to reduce refrigeration system is evaporative cooling system. The aim of the research is to investigate characteristic of air conditioning inside the house wich utilize evaporative cooling system using Computational fluids dynamics (CFD ). The research was done by describing 3 different times which are 09.00-10.00 (in the morning), 12.00-13.00 (at noon) and 19.00-20.00 (at night) with incoming air in different properties. The air characteristic test was done by measuring velocity of the wind, relative humidity (RH) and temperatures at 28 positions of measurement cup (PU), where PU were spreaded at 3 places, (1) in front of the house; (2) at the interior; and (3) at the exterior. The measurement was conducted by making square plane of 2x2m with high of 1.5 m above floor of 28 PU. CFD simulation results showed that the cooling effect evaporative felt on the 1st floor with the average temperature reduction of 1.5 oC from the ambient temperature and increase RH of 6.75 % from ambient RH. While the vertical ventilation work effectively in supporting air circulation. The movement of the wind can be felt throughout the house with the average velocity of 0,175 m/s. Key Words : Comfort zone, Evaporative cooling, CFD
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | Comfort zone, Evaporative cooling, CFD |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TD Environmental technology. Sanitary engineering T Technology > TJ Mechanical engineering and machinery T Technology > TX Home economics |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | RISKI YOGA NANDA |
Date Deposited: | 20 Dec 2016 11:42 |
Last Modified: | 21 Dec 2016 03:22 |
URI: | http://eprints.ums.ac.id/id/eprint/48116 |