Heri Setyawan, Riyan and , Wijianto, ST., M.Eng.Sc and , Ir. Pramuko IP, MT (2016) Karakteristik Komposit Serat Enceng Gondok Dengan Fraksi Volume 15%, 20%, 25% Terhadap Uji Bending, Uji Tarik Dan Daya Serap Bunyi Untuk Dinding Peredam Suara. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (PUBLIKASI ILMIAH)
PUBLIKASI ILMIAH.pdf Download (1MB) |
|
PDF (HALAMAN DEPAN)
COVER DLL.pdf Download (1MB) |
|
PDF (BAB I)
BAB I.pdf Download (93kB) |
|
PDF (BAB II)
BAB II.pdf Restricted to Repository staff only Download (820kB) |
|
PDF (BAB III)
BAB III.pdf Restricted to Repository staff only Download (1MB) |
|
PDF (BAB IV)
BAB IV.pdf Restricted to Repository staff only Download (197kB) |
|
PDF (BAB V)
BAB V.pdf Restricted to Repository staff only Download (88kB) |
|
PDF (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf Download (6kB) |
|
PDF (LAMPIRAN)
LAMPIRAN.pdf Restricted to Repository staff only Download (6MB) |
|
PDF (PERNYATAAN PUBLIKASI ILMIAH)
PERNYATAAN PUBLIKASI ILMIAH.pdf Restricted to Repository staff only Download (329kB) |
Abstract
Purpose of the research is to know tensile strength and bending strength of water hyacinth (eceng gondok) composite at variation of volume fraction of 15%, 20% and 25% with standards of ASTM D 3039 and ASTM D 799-99, andalso, capability of sound absorption with sponge layer and plywood layer and without those layers are also researched with ANSI S1.13-05 standards. Primary material of the research is water hyacinth fiber with polyester matrix of BQTN 157. Main variable of the research is volume fractions of 15%, 20% and 25% fibers with procedure of tensile test referring to ASTM D 3039, the bending test refers to ASTM D 799-9 and the test of sound absorption refers to ANSI S1.13-05. Results of the research indicated that the average highest tensile strength of was found at volume fraction of 25%, namely 131.76 MPa and the lowest one was found at volume fraction of 15%, namely 59.69 MPa and the average highest modulus of elasticity was found at volume fraction of 25%, namely 17989.61 MPa and the lowest one was found at volume fraction of 15%, namely 8149.27 MPA. The average highesttensile strength of 30.41 MPa was found at volume fraction of 25% and the lowest one of 12.43 MPa was found at volume fraction of 15% and the average highest modulus of elasticityof 1265.15 MPa was found at volume fraction of 25% and the lowest one of 996.82 was found at volume fraction of 15%. The highest sound absorption without plywood and plank layers was found at volume fraction of 25%, namely 1.34 dB and the lowest one was found at volume fraction of 15%, namely 0.21 dB. While, the highest value of sound absorption with the use of layers was found at volume fraction of 25%, namely 1.66 dB and the lowest one was found at volume fraction of 15%, namely 0.67 dB.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | composite, water hyacinth fiber, volume fraction |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | RIYAN HERI SETYAWAN |
Date Deposited: | 15 Aug 2016 01:23 |
Last Modified: | 15 Aug 2016 01:23 |
URI: | http://eprints.ums.ac.id/id/eprint/45940 |