Sari, Neni Anggoro and , Mochamad Solikin, S.T., M.T., Ph.D and , Yenny Nurchasanah, S.T., M.T. (2016) Pemanfaatan Teknologi High Volume Fly Ash Concrete Untuk Memproduksi Beton Kuat Tekan Normal. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (NASKAH PUBLIKASI)
1. NASKAH PUBLIKASI ILMIAH.pdf Download (702kB) |
|
PDF (HALAMAN DEPAN)
2. Cover.pdf Download (786kB) |
|
PDF (BAB I)
3. BAB I.pdf Download (67kB) |
|
PDF (BAB II)
4. BAB II.pdf Restricted to Repository staff only Download (221kB) | Request a copy |
|
PDF (BAB III)
5. BAB III.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (BAB IV)
6. BAB IV.pdf Restricted to Repository staff only Download (621kB) | Request a copy |
|
PDF (BAB V)
7. BAB V.pdf Restricted to Repository staff only Download (378kB) | Request a copy |
|
PDF (BAB VI)
8. BAB VI.pdf Restricted to Repository staff only Download (11kB) | Request a copy |
|
PDF (DAFTAR PUSTAKA)
9. Daftar Pustaka.pdf Download (6kB) |
|
PDF (LAMPIRAN)
10. LAMPIRAN.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
PDF (PERNYATAAN PUBLIKASI ILMIAH)
11. surat pernyataan publikasi ilmiah.pdf Restricted to Repository staff only Download (330kB) | Request a copy |
Abstract
Concrete technology has developed very rapidly, so concrete supporting materials wich able to modify the properties and characteristics of the concrete in order to facilitate the work or energy saving are needed. The use of fly ash as a fine powder added material to replace cement up to 50% (high volume fly ash) was striving to be used as a useful material. This research was conducted by examining the development of compressive strength of normal concrete, high volume fly ash concrete with the addition of chemicals superplasticizer as much as 1% by using low fas at 14 days, 28 days, 56 days and testing the value of water absorption of concrete on 56 days. The result of reviews of mpressive strength for normal concrete, HVFA concrete and HVFA-SP concrete at 14 days respectively was 18,109 MPa 9,620 MPa and 4,716 MPa, at 28 days respectively was 19,241 MPa 10,186 MPa and 8,300 MPa, at 56 days respectively was 19,618 MPa 16,600 MPa and 12,450 MPa. The test result of water absorption concrete at 56 days each were 7,832% 7,597% and 6,745%. The compressive strength of high volume fly ash concrete decreased than the compressive strength of normal concrete, fine powder of fly ash as a concrete additive can be tested in the field by conducting further studies to obtain the compressive strength of concrete optimally. Concrete water absorption value of high volume fly ash concrete was smaller than normal concrete, this was very good because it can prevent cracks smooth concrete surface.
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | fly ash, high volume fly ash concrete, superplaticizer |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Fakultas Teknik > Teknik Sipil |
Depositing User: | NENI ANGGORO SARI |
Date Deposited: | 16 Aug 2016 04:02 |
Last Modified: | 16 Aug 2016 04:02 |
URI: | http://eprints.ums.ac.id/id/eprint/45051 |
Actions (login required)
View Item |