Hartadi, Setia (2016) Tinjauan Kuat Tekan Dan Kuat Lentur Dinding Panel Dengan Menggunakan Perkuatan Diagonal Tulangan Baja. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
naskah publikasi.pdf Download (248kB) |
|
PDF (Halaman Depan)
Cover dan lain-lain.pdf Download (224kB) |
|
PDF (Bab I)
BAB I.pdf Download (26kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (96kB) |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (90kB) |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (587kB) |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (257kB) |
|
PDF (Bab VI)
BAB VI.pdf Restricted to Repository staff only Download (24kB) |
|
PDF (Daftar Pustaka)
DAFTAR PUSTAKA.pdf Download (7kB) |
|
PDF (Lampiran)
Lampiran.pdf Restricted to Repository staff only Download (1MB) |
Abstract
ABSTRACTION Along with the rapid development of the current development , the use of brick as a building wall can be replaced with a wall panel usage . Wall panel is one of the technological developments in the field of precast concrete ( precast) . Precast wall ( precast) is not a structural element , which has sought to use a relatively light weight so it does not place an increased burden for the structure of the building . In this study aims to determine how much the compressive strength and flexural strength reinforcement diagonal wall panels without steel reinforcement and wall panels with a diagonal reinforcement steel reinforcement. Reinforcing steel is a material that has a high tensile strength. In this study attempted reinforcing steel reinforcement is applied as a diagonal with water factor cement (fas) of 0.45. the sample used is a concrete cylinder with a height of 15 cm and a diameter of 30 cm sebanyk 5 pieces, wall panels with a length of 100 cm, width of 50 cm and a height of 7 cm 16 units. From the results of research conducted at the Laboratory of Building Materials, Department of Civil Engineering, Faculty of Engineering, Universitas Muhammadiyah Surakarta, obtained an average density of concrete cylinders of 1,709 gr / cm3, so it can be classified as lightweight concrete, with an average compressive strength of 5.83 MPa, whereas the compressive strength testing panel wall without diagonal reinforcement steel reinforcement of 2,094 MPa, while the average value of the compressive strength of a wall panel with a diagonal reinforcement of 2,472 MPa steel reinforcement, of the research results using the value of the diagonal reinforcement steel the higher the compressive strength. In the flexural strength testing panel wall without diagonal reinforcement steel reinforcement amounting to 2.755 MPa, while the average value of flexural strength reinforcement wall panel with a diagonal of 7.214 MPa steel reinforcement, of the results of these studiesby using steel reinforcement diagonal then the higher the compressive strength. Keywords : Wall Panels , Compressive Strength , Strong Flexible, Diagonal Reinforcement Steel Reinforcement
Item Type: | Karya ilmiah (Skripsi) |
---|---|
Uncontrolled Keywords: | Dinding Panel, Kuat Tekan, Kuat Lentur, Perkuatan Diagonal Tulangan Baja |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Fakultas Teknik > Teknik Sipil |
Depositing User: | Unnamed user with username d100110087 |
Date Deposited: | 13 Jan 2016 01:50 |
Last Modified: | 13 Jan 2016 01:50 |