Hadipurwa, Dwi Angga and , Dwi Rosella Komalasari S.Fis, M.Fis (2015) Penatalaksanaan Fisioterapi Pada Kondisi Post Fraktur Olecranon Sinistra Dengan Pemasangan Plate And Screw Di RST Dr Soedjono Magelang. Diploma thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
11. NASKAH PUBLIKASI.pdf Download (248kB) |
|
PDF (Halaman Depan)
02. HALAMAN DEPAN FIX.pdf Download (278kB) |
|
PDF (Bab I)
03. BAB I.pdf Download (95kB) |
|
PDF (Bab II)
04. BAB II.pdf Restricted to Repository staff only Download (629kB) |
|
PDF (Bab III)
05. BAB III.pdf Restricted to Repository staff only Download (228kB) |
|
PDF (Bab IV)
06. BAB IV.pdf Restricted to Repository staff only Download (123kB) |
|
PDF (Bab V)
07. BAB V.pdf Restricted to Repository staff only Download (156kB) |
|
PDF (Daftar Pustaka)
08. DAFTAR PUSTAKA.pdf Download (132kB) |
|
PDF (Lampiran)
09. LAMPIRAN.pdf Restricted to Repository staff only Download (527kB) |
|
PDF (Surat Pernyataan Publikasi)
01. SURAT PERNYATAAN PUBLIKASI KARYA ILMIAH.pdf Restricted to Repository staff only Download (132kB) |
Abstract
Background: Fracture the olecranon sinistra is a condition in which bone is lost ulnar proximal left that due to the pressure, overload, extreme movement so that the bone is not able to withstand. Aim of Research: To know the management of physiotherapy in reducing pain, increasing range of motion, maintaining muscle strength in patients post fractures the olecranon sinistra with mounting plate and screw by using modalities Infra red and Therapeutic Exercise. Results: After terapy for about six times the obtained result reduction in the degree of pain, in motion pain T1: 3.3 to T6: 0. increase loop segment 5 cm above T1: 23 cm to T6: 24 cm, 5 cm down T1: 26 cm to T6: 27 cm, 10 cm and above T1: 23 cm to T6: 24 cm, 10 cm down T1: 24 cm to T6: 25 cm. increase muscle strength in flexion T1: 4 to T6: 4, extensions T1: 4 to T6: 4. Increased range of motion S: T1: 2,50-300-800 to T6: 30-200-900. Conclusion: Infra Red can reduce pain in the case of post fracture the olecranon sinistra with mounting plate and screw. Exercise Therapy can increase the range of motion and increase muscle strength in the case of post fracture the olecranon sinistra with mounting plate and screw.
Item Type: | Karya ilmiah (Diploma) |
---|---|
Uncontrolled Keywords: | Post Fracture, Plate and Screw, Infrared, Therapeutic Exercise. |
Subjects: | R Medicine > R Medicine (General) R Medicine > RM Therapeutics. Pharmacology |
Divisions: | Fakultas Ilmu Kesehatan > Fisioterapi D3 |
Depositing User: | Cahyana K. Widada |
Date Deposited: | 26 Nov 2015 10:47 |
Last Modified: | 11 Oct 2021 02:07 |
URI: | http://eprints.ums.ac.id/id/eprint/39644 |
Actions (login required)
View Item |