Praszita, Atthariq and , Ir. Mochamad Solikin, S.T., M.T., Ph.D (2023) Design 10 Story Hospital Building in Klaten with Direct Displacement Based Design. Skripsi thesis, Universitas Muhammadiyah Surakarta.
PDF (Naskah Publikasi)
Naskah Publikasi.pdf Download (424kB) |
|
PDF (Halaman Depan)
Halaman Depan.pdf Download (3MB) |
|
PDF (Bab I)
BAB I.pdf Download (787kB) |
|
PDF (Bab II)
BAB II.pdf Restricted to Repository staff only Download (633kB) |
|
PDF (Bab III)
BAB III.pdf Restricted to Repository staff only Download (1MB) |
|
PDF (Bab IV)
BAB IV.pdf Restricted to Repository staff only Download (455kB) |
|
PDF (Bab V)
BAB V.pdf Restricted to Repository staff only Download (9MB) |
|
PDF (Bab VI)
BAB VI.pdf Restricted to Repository staff only Download (6MB) |
|
PDF (Bab VII)
BAB VII.pdf Restricted to Repository staff only Download (11MB) |
|
PDF (Bab VIII)
BAB VIII.pdf Restricted to Repository staff only Download (2MB) |
|
PDF (Bab IX)
BAB IX.pdf Restricted to Repository staff only Download (309kB) |
|
PDF (Daftar Pustaka)
Daftar Pustaka.pdf Download (186kB) |
|
PDF (Lampiran)
Lampiran.pdf Restricted to Repository staff only Download (24MB) |
|
PDF (Surat Pernyataan Publikasi)
Surat Pernyataan Publikasi.pdf Restricted to Repository staff only Download (745kB) |
Abstract
Indonesia as a country located inside ring of fire made this country have prone to earthquake. It forced the structure engineer to build design as efficient as possible to resulting the adequate building design. Direct Displacement Based Design (DDBD) is a method which developed as an alternative to design the structure as efficient due to the performance of the building. This final project was designing 10 stories hospital building located in Klaten, Central Java, Indonesia. The structure using dual system structure and stand above the middle soil classification. The applied earthquake loads in the building conduct by Direct Displacement Based Design method then detailing by SNI 2847:2013 code. The design evaluated by conducting Nonlinear Static Pushover Analysis to acknowledge the performance according to FEMA 440. The result shows that the performance point of the structure is on immediate occupancy and meet the hospital design criteria. Drift result showing 0,004 for x direction and 0,005 for y direction. According to deformation limit at Table 11 – 4, ATC-40 for hospital building importance, performance target only allows on immediate occupancy level, which the maximum inelastic drift is 0,005. Due to the inelastic drift result, the structure meets the design criteria for Immediate Occupancy performance level on X and Y direction.
Item Type: | Thesis (Skripsi) |
---|---|
Uncontrolled Keywords: | DDBD, Nonlinear Static Pushover, Seismic Engineering |
Subjects: | T Technology > TA Civil Engineering T Technology > TH Building construction |