Analisis Kinerja PMT Dan Recloser Di Jaringan Distribusi 20 KV Pada PT PLN (Persero) UP3 Klaten

Wulandari, Puri Retno Ayu and , Agus Supardi, S.T., M.T (2022) Analisis Kinerja PMT Dan Recloser Di Jaringan Distribusi 20 KV Pada PT PLN (Persero) UP3 Klaten. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
Naskah Publikasi.pdf

Download (606kB)
[img] PDF (Surat Pernyataan Publikasi)
Surat Pernyataan.pdf
Restricted to Repository staff only

Download (70kB)

Abstract

The needs of the community that needs to be fulfilled one of them is electrical energy. Therefore, the distribution system should have protection in the distribution of electricity systems to ensure the reliability and continuity of electrical energy when supporting human activities. Protection equipment on the distribution network plays a role in breaking disruption that can lead to the widespread area of the blackout. Setting the protection of the protection of the network affects the magnitude of the short circuit interface. Protection equipment needs to be coordinated that no disruption disruption that causes on consumer losses. This research has a goal to know the performance of PMT and recloser during interruption and simulate with Etap 12.6.0 software and compare the results of the calculation and the simulation. In this study using a literature study research method and data methods of PT PLN (Persero) UP3 Klaten. The data is processed and matured mathematically later simulated on Etap 12.6.0 software. The results of the scales of short circuit flows on PMT have the calculation of 8.452 KA, on the 9th bus calculation of 3.342 KA, at reloser 1 calculation of 1.939 ka, at recloser 2 calculations of 1.905 ka. The results of this calculation are no different from the simulation results. At the time of occurrence of recloser 2 has an operation time (t) of 0.297 s, recloser 1 amounted to 0.596 s, and OCR of 0.998 s. Simulation on Etap software on Bus 3 and Bus 9 When there is 3 Phasa interference then PMT will open with the help of OCR relays to provide open signal to PMT while, on bus 25 and bus 27 when there is 3 distress interference then recloser will lock-out/open.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Short Circuit Current, PMT, Recloser, ETAP Software
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: PURI RETNO AYU WULANDARI
Date Deposited: 29 Jul 2022 11:01
Last Modified: 29 Jul 2022 11:01
URI: http://eprints.ums.ac.id/id/eprint/102078