Analisis Kinerja Sistem Proteksi Akibat Gangguan Hubung Singkat Di Gardu Induk Jajar 150 kV Dengan Menggunakan Software ETAP 12.6.0

Amelinda, Chyntia Risa and , Umar, S.T., M.T, (2022) Analisis Kinerja Sistem Proteksi Akibat Gangguan Hubung Singkat Di Gardu Induk Jajar 150 kV Dengan Menggunakan Software ETAP 12.6.0. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Naskah Publikasi)
Naskah Publikasi Chyntia Risa Amelinda.pdf

Download (803kB)
[img] PDF (Surat Pernyataan Publikasi)
Surat Pernyataan Publikasi Ilmiah.pdf
Restricted to Repository staff only

Download (338kB)

Abstract

Power Circuit Breaker (PMT) is a breaker device installed in a substration which has the function of connecting and disconnecting electrical circuits under load. The installation of circuit breaker is intended to avoid damage to substation equipment which will cause delays in the distribution of electricity to the load (consumers). The purpose of this study was to analyze the work of the circuit breaker when experiencing a short circuit current and to simulate the results of research at the 150 kV Jajar Substation regarding disturbances that occur in the field. This study uses several methods, namely conducting research and data collection at the 150 kV Jajar Substation. The data is then processed and calculated mathematically and then simulated on the ETAP 12.6.0 software to compare the results. After mathematical calculations, the results obtained are the 150 kV side source impedance of 225 ohms, the 20 kV side source impedance of 4 ohms, the positive and negative sequence reactances of j0.22283 pu, the positive and negative sequence impedances of the 150 kV sides of j0.0275 pu and the positive and negative sequence impedance of the 20 kV side is 0.0336+j0.078951 pu. Calculation of short-circuit fault on the 150 kV side obtained results of 13961,4 A and on the 20 kV side of 20178,18 A. Perform calculations on overcurrent relay settings on each side to set the PMT side to trip when a disturbance occurs. The results of the calculation of the standard time setting relay (TMS) on the 20 kV outgoing side of 0.3 and on the incoming 20 kV side of 0.31.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: pemutus tenaga, software ETAP 12.6.0, trafo, gardu induk.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: CHYNTIA RISA AMELINDA
Date Deposited: 13 Jul 2022 07:57
Last Modified: 13 Jul 2022 07:57
URI: http://eprints.ums.ac.id/id/eprint/100973

Actions (login required)

View Item View Item