Evaluasi Perhitungan Gangguan Hubung Singkat Pada Sistem Tenaga Listrik Penyulang BWN-9 Gardu Induk Bawen

Pratama, Adhitya Aji and -, Ir.Jatmiko,M.T (2019) Evaluasi Perhitungan Gangguan Hubung Singkat Pada Sistem Tenaga Listrik Penyulang BWN-9 Gardu Induk Bawen. Skripsi thesis, Universitas Muhammadiyah Surakarta.

[img] PDF (Pernyataan Publikasi Ilmiah)
surat pernyataan.pdf
Restricted to Repository staff only

Download (93kB) | Request a copy
[img] PDF (Naskah Publikasi Ilmiah)
D400140032_ADHITYA AJI PRATAMA_TEKNIK ELEKTRO.pdf

Download (1MB)

Abstract

Manufacture of electric power system requires a planning. An evaluation of the calculation of short circuit interruption is indispensable in terms of planning. A short circuit is very often occurs in a system. A short circuit caused due to a carriage-voltage connected to the neutral conductor and is very harmful to electrical equipment that does not have custody or protection because of the current flow is too large. Efforts that can be done is to do an evaluation of the calculation against a short circuit in order to megetahuai the current short circuit could have been flowing in the system and determines the set of systems or proteki on the system. The research discusses the evaluation of the current short circuit calculation of three-phase, two phase, two phase to ground and single phase to ground at the penyulang booth holding 9-BWN Bawen. Pegumpulan data in the form of single line diagrams complete with load data and conducting data done to run a simulation of short circuit on the ETAP Power Station 12.6. The simulation is performed by specifying three point short circuit interruption, in areas closer to the source, the area close to the load and the area between the source with the load. The simulation showed the big three short arushubung phase, two phase, two phase to ground and single phase to ground. The location of the point of interruption is of great influence in the small increase in the event of a short circuit current. The increase in current will be even greater when a short circuit is close to the source.

Item Type: Karya ilmiah (Skripsi)
Uncontrolled Keywords: short circuit, power system, ETAP Power Station 12.6
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: ADHITYA AJI PRATAMA
Date Deposited: 27 Aug 2019 03:52
Last Modified: 27 Aug 2019 03:52
URI: http://eprints.ums.ac.id/id/eprint/77294